Implantation of Cardioverter Defibrillator
Cardioverter-defibrillator (ICD) implantation is a procedure during which a small device is implanted under the skin to monitor the heart rhythm and, when necessary, automatically restore a normal heartbeat.
What is an implantable cardioverter-defibrillator (ICD)?
An ICD is an electronic device that continuously monitors the heart's activity. If the heart begins to beat too quickly and irregularly (for example, ventricular tachycardia or ventricular fibrillation), the ICD automatically delivers an electrical shock (defibrillation) to restore a normal heart rhythm. Some ICDs can also function as pacemakers if the heart rate becomes too slow.
When is ICD implantation considered?
- Patients who have survived sudden cardiac arrest and have been successfully resuscitated.
- Patients with certain heart conditions, such as severe heart failure, ischemic heart disease, or cardiomyopathy, which increase the risk of ventricular tachycardia or ventricular fibrillation.
- Patients with congenital or inherited conditions that cause heart rhythm disorders.
How is the procedure performed?
ICD implantation is usually performed under local anesthesia, sometimes with mild sedation. During the procedure:
- Preparation: the patient is prepared for the procedure, the skin is disinfected, and sterile drapes are applied.
- Incision: a small incision is made in the chest area, usually below the collarbone.
- Lead insertion: thin wires (leads) are inserted through a vein into the chambers of the heart. Using X-ray guidance, the physician ensures that the leads are properly attached to the heart muscle.
- Device connection and implantation: the leads are connected to the ICD device, which is placed into a pocket created beneath the skin.
- Testing: before the incision is closed, the device is tested to ensure that it functions properly and can detect and correct heart rhythm disturbances. In some cases, a so-called “defibrillation threshold test” is performed, during which a brief arrhythmia is induced to verify that the ICD can successfully terminate it.
- Closure of the incision: the incision is closed with sutures.
The entire procedure usually takes 1 to 3 hours.
After the procedure: Following implantation, the patient is monitored in the hospital for a period of time. Mild pain or discomfort at the incision site may occur. Regular ICD check-ups are performed to assess device function and battery status. The battery typically lasts 5 to 10 years, after which the device must be replaced.